General Features:
They are used in places where high measurement precision is not required.
They are used in pressure measurements of liquids and gases that are not corrosive to copper alloys.
Body Diameter: Ø40 mm
Pressure Range: 0-100 bar
Sensitivity: ± \%2.5 (KL. 2.5)
Liquid filled types are used in environments with pulsed pressure or vibration.
Fluid Temperature: +60 °C
Working Pressure: Full Scale x \%75
Compatibility: EN837/1 Standard
Protection Class: IP41
Industrial Sector: Water treatment, machine manufacturers, heating and air conditioning machines, Pumps/compressors hydraulic systems and pressure lines.
Areas of Use:
They are used in pressure measurements of liquids and gases that are not corrosive to copper alloys.
Air Conditioners,
Compressed Air Lines,
Healthcare Devices,
Hydraulic Systems,
Heating Systems,
Water Pumps,
Water Circulation Systems, etc.
Structural Features
Mounting Type: Bottom Connection
Unit of Measurement : bar/psi
Measurement Range : 0/100
Body : Plastic (ABS)
View Plate : Polycarbonate
Mechanism : Brass
Pressure Organ : Copper Alloy
Connection : G 1/8’’ B
Dial : Aluminum
Needle : Plastic
Joint Welding : Solder
Usage Features
Fluid Temperature : Maximum + 60 °C
Ambient Temperature : -40...+60 °C
Working Pressure (max.) : Must not exceed maximum 75% of full scale value.
Overpressure Limit : ≤40 bar PN x 1.25
Accuracy Class : KL 2.5
Protection Class : IP 41
Optimum Measuring Range : Between 0.1 x PN and 0.75 x PN
Storage Temperatures : -40 ... +70 °C
Compliance : EN 837 - 1
Mechanical Shock Test Load : 15g
Mechanical Vibration Test : 10 Hz to 150 Hz -1 octave/min. 2s / 3 axes
Pakkens Diameter : 40 Bar Alt. Dry Manometer