FAST SHIPPING!
FAST SHIPPING!
Dundar CM 16.4H Hot Environment Radial Snail Fan (Single Phase) 120 Degrees 750 m³ 1460 RPM
Dundar CM 16.4H Hot Environment Radial Snail Fan (Single Phase) 120 Degrees 750 m³ 1460 RPM

DÜNDAR

Dundar CM 16.4H Hot Environment Radial Snail Fan (Single Phase) 120 Degrees 750 m³ 1460 RPM

Product Code:104164120
Stock:10
Share:
WhatsApp
ADD TO BASKET
Product Description
Delivery&Returns

Ürün Tipi

V

AC/DC

Hz

W

rpm

m3/h

Ağırlık

CM 16.2 H

220

AC

50

140

1460

750

9,6

 Dündar CM 16.4H Sıcak Ortam Radyal Salyangoz Fan
 

 MODEL  C  D  E  H  L  O P S T
 CM 16.4H  310  180  280  350  142  140 110 130 145


What is a Hot Environment Fan?

Dündar Hot Environment fans are specially designed centrifugal fans capable of handling temperatures up to 120 degrees. They are used for ventilating and cooling existing environments.

Applications of Hot Environment Fans

  • Exhausting hot air in areas with high temperatures
  • In duct applications where axial fans fail to meet pressure and flow requirements
  • In solid fuel boiler systems
Fan Casing and Impeller

  • Ability to discharge higher-temperature air with an intermediate cooling impeller that prevents heat transfer from the radial casing to the motor
  • Radial casing made from high-quality cold-drawn steel sheet
  • Environmentally friendly and corrosion-resistant electrostatic epoxy powder coating
  • Radial impeller with dynamic balancing test according to ISO 1940 standards for forward-looking performance
  • High-pressure and flow rates with nozzle application at the inlet
  • Robust and smooth casing structure with special joint casing assembly
  • Low Noise Level
Motor

  • Quality production through high-tech CNC machines, without human intervention
  • High heat transfer capacity aluminum framed motor housing
  • Insulation class Class F for a wide operating range from -40° to +70°
  • Things to Consider in Fan Selection
  • When selecting a fan, four parameters must be taken into consideration:
  • Required Airflow
  • Pressure Losses
  • Acceptable Noise Level
  • Electrical Power Connection Type
The required air change rate for a ventilated space depends on the usage purpose, the number of people and objects inside, and activities within. Below, different environments and their required air change coefficients are provided.

EnvironmentAir Change Coefficient
Auditoriums6-8
Paint Booths25-50
Vault Rooms3-6
Cinemas and Theaters5-8
Commercial Kitchens15-30
Foundries8-15
Gymnasiums4-6
Laundry Rooms10-20
Indoor Pools3-4
Restaurants8-12
Conference Rooms6-8
Waiting Rooms / Copy Rooms / Machine Rooms10-40
Shops4-8
Dry Cleaning5-15
General Manufacturing Areas4-8
Hospitals8-12
Laboratories8-15

For normal activity (non-smoking), 29 m³/hour is required per person. For normal activity (smoking), 58 m³/hour is required per person. For light activity, 45 m³/hour is needed per person. For heavy industrial activities, 60 m³/hour is necessary per person.

Based on the provided information, the required airflow is determined as follows:

Q [m³/hour] = Air change coefficient (per hour) * Room volume (m³) or
Q [m³/hour] = Number of people * airflow requirement per person
Once the required airflow is determined, a suitable duct design must be made (taking into account sound and airflow velocity criteria), and pressure losses must be calculated. Depending on the environment in which the fan will operate, the fan type (axial, radial, roof, smoke exhaust, etc.) should be selected, and based on the determined airflow-static pressure pair, the appropriate fan curve should be chosen. To illustrate briefly:

For an office where 5 people work, with a ceiling height of 2.6 meters and a floor area of 50 m², the total volume is 2.6 * 50 = 130 m³. Referring to the air change coefficient table for offices, the value provided is 4-8. Considering 5, 130 * 5 = 650 m³/h airflow is needed. Assuming normal activity, 5 people * 29 m³ = 145 m³ airflow is required. Thus, for the workers, the total airflow needed is 650 + 145 = 795 m³/hour. The fan selection should be made according to this airflow requirement.

Comments
Comment
There are no comments for this product yet.

Similar Products

Dundar CM 21.4H Hot Environment Radial Snail Fan (Single Phase) 120 Degrees 1575 m³ 1390 RPM

Dundar CM 21.4H Hot Environment Radial Snail Fan (Single Phase) 120 Degrees 1575 m³ 1390 RPM

Dundar CT 18.2H Hot Environment Radial Snail Fans (Three Phase) 120 Degrees 1700 m³ 2770 RPM

Dundar CT 18.2H Hot Environment Radial Snail Fans (Three Phase) 120 Degrees 1700 m³ 2770 RPM

Dundar CM 21.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 2500 m³ 2700 RPM

Dundar CM 21.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 2500 m³ 2700 RPM

Dündar CT 18.4H Hot Environment Radial Snail Fans (Three Phase) 120 Degrees 1100 m³ 1445 RPM

Dündar CT 18.4H Hot Environment Radial Snail Fans (Three Phase) 120 Degrees 1100 m³ 1445 RPM

Dundar CM 18.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 1625 m³ 2650 RPM

Dundar CM 18.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 1625 m³ 2650 RPM

Dundar CM 16.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 1500 m³ 2700 RPM

Dundar CM 16.2H Hot Environment Radial Snail Fan (Single Phase) 120 Degree 1500 m³ 2700 RPM